For many titrations, a potentiometric determination of the equivalence point is simply not possible. However, manually performing complexometric titrations can be inaccurate due to ambiguous color changes and when using non-aqueous or semi-opaque liquids, such as lubricating oils. In these cases, the use of a photometric probe for the optical determination of an endpoint during volumetric analysis is preferred. Hanna Instruments introduces HI900603 photometric electrode for when a color change is still the best solution.
Out of stock
The HI900603 photometric electrode has a yellow LED with a wavelength of 590 nm as a light source. This wavelength of light is useful for determining yellow or blue endpoints when using indicators such as xylenol and methylthymol blue during a volumetric titration. The HI900603 can be used to measure the concentration of:

HI900603 uses a LED that emits light at 590 nm (yellow color). This high quality LED will provide long term use since it takes thousands of hours for the LED intensity to dim naturally.
The HI900603 contains a glass flow through cell, which the sample fills. The LED shines light at 590 nm through the sample, which is reflected back by a platinum mirror sealed in the glass tip of the probe. The fixed path length of the reflective measurement allows for high color sensitivity in a compact design.
All readings are compensated for the changes in temperature of the sample from 0 to 75℃ (32 to 167℉) to provide for accurate and repeatable measurements.

HI900603 probe has a glass-body that offers excellent chemical resistance against organic solvents. These solvents can be found in samples and can attack different forms of plastics.
The electronics of the probe are located in a steel shielding, which is covered by the glass-body. The steel sheilding of the probe also blocks out ambient light and protects against electronic interference.
HI900603 has a probe diameter of 12 mm (1/2″), which is the standard size for most pH/ORP electrodes. The 12 mm probe will fit in most electrode holders.

HI900603 has a BNC connector for connecting a pH/mV input of a meter. The mV range for the probe is from 10 to 1100 mV.
A PS/2 connector is used for supply power to the probe. The HI931and HI932 potentiometric titration systems have a ps/2 power output for the probe to be connected to. The HI900932 is a PS/2 Y-splitter that is also available and allows for multiple probes to use one power source.
Although the LED provides a very long life, it does slowly dim over time. A trimmer located in the head of the probe can be used to adjust the output intensity. This allows the probe to be recalibrated, ensuring accurate measurements. The probe is placed in DI or distilled water and the trimmer adjusted until 1000 mV (100% transmittance) is displayed.
Have questions about our products or need help selecting the right laboratory equipment or chemicals? Fill out the form below, and our team will get back to you with the best solution for your business or laboratory.